EMS Fan Expert
Products › SDS Tunnel Jet Fan
EMS Industrial Fan Solutions

SDS Tunnel Jet Fan

Product Overview

The SDS Tunnel Jet Fan is an axial-flow jet fan designed for longitudinal ventilation in road tunnels, highway tunnels, underground roads, transportation tunnels, and other large underground facilities.

By generating high-velocity airflow and jet thrust, the fan transfers momentum to the surrounding tunnel air and drives longitudinal airflow through the tunnel. It can be used for normal ventilation, pollutant removal, airflow control, and smoke management during fire emergencies.

EMS provides SDS Tunnel Jet Fans with customized airflow, jet thrust, motor power, reversible operation, high-temperature configuration, mounting systems, and electrical control solutions according to individual tunnel projects.

Main Applications

SDS Tunnel Jet Fans are suitable for:

Road Tunnel Ventilation

Highway Tunnel Ventilation

Urban Road Tunnel Ventilation

Underground Road Ventilation

Railway and Transit Tunnels

Underground Parking Facilities

Long Underground Passages

Tunnel Pollutant Exhaust

Tunnel Smoke Control

Fire Smoke Management

Longitudinal Tunnel Ventilation

Underground Transportation Facilities

Typical Technical Parameters

ParameterTypical Range
Product TypeTunnel Jet Fan
Fan Diameter500–1600 mm
Airflow20,000–150,000 m³/h
Jet Velocity20–40 m/s
Jet Thrust300–2,500 N
Motor Power7.5–160 kW
Motor Speed1,450–2,980 rpm
Operating Temperature-20°C to +60°C
High-Temperature OperationOptional
Airflow DirectionForward / Reversible
Drive TypeDirect Drive
Impeller TypeAxial Flow
Casing MaterialCarbon Steel / Stainless Steel
MotorIndustrial / Tunnel Ventilation Motor
InstallationCeiling / Side Mounting
ControlDOL / Soft Starter / VFD
DutyContinuous Operation

The above values are typical engineering reference ranges rather than fixed specifications for every SDS model. Final fan performance should be selected according to the tunnel ventilation calculation, required jet thrust, smoke-control conditions, and applicable project standards.

Working Principle

The SDS Tunnel Jet Fan uses an axial impeller to accelerate air through the fan and generate a high-speed jet.

The resulting jet exchanges momentum with the surrounding tunnel air, creating longitudinal airflow along the tunnel.

Typical ventilation flow:

Fresh Air → SDS Jet Fan → Longitudinal Airflow → Pollutant Exhaust

For emergency smoke-control applications, multiple jet fans can be strategically installed and controlled to manage smoke movement and support the tunnel's fire safety ventilation system.

Key Features

High Jet Thrust

The aerodynamic design of the axial impeller and internal airflow passage is optimized to generate effective jet thrust for tunnel longitudinal ventilation.

Reversible Operation

Reversible configurations can be provided for projects requiring bidirectional airflow or specific smoke-control strategies.

Compact Installation

Jet fans are normally suspended from the tunnel ceiling or mounted on brackets, minimizing the need for large ventilation ducts.

Direct Drive

The direct-drive configuration reduces mechanical transmission components and simplifies inspection and maintenance.

High-Temperature Configuration

For fire smoke-control applications, the fan can be engineered with appropriate high-temperature materials, motor configuration, insulation, and other components according to the required duty.

Customized Engineering

EMS can select and customize the fan according to tunnel length, cross-sectional area, ventilation resistance, required airflow, jet thrust, installation conditions, power supply, and smoke-control requirements.

Typical Installation Locations

SDS Tunnel Jet Fans can be installed in:

Tunnel ceilings

Tunnel roofs

Tunnel side walls

Ventilation sections

Underground roadways

Smoke-control zones

Underground transportation facilities

Multiple jet fans can be arranged according to the tunnel ventilation design to establish the required longitudinal airflow pattern.

Fan Selection Information

To select the appropriate SDS Tunnel Jet Fan, the following information is recommended:

Tunnel Length

Tunnel Cross-Section

Tunnel Height

Traffic Volume

Required Airflow

Required Jet Thrust

Ventilation Method

Ventilation Resistance

Smoke Extraction Requirement

Fire Temperature Requirement

Fan Installation Height

Power Supply

Voltage and Frequency

Reversible Operation Requirement

Noise Requirement

Required Fan Quantity

EMS can provide fan selection and engineering recommendations based on the actual project conditions.

EMS Engineering & Customization Services

EMS provides more than standard tunnel jet fans. Our engineering support can include:

Fan Selection

Performance Matching

Airflow and Pressure Calculation

Jet Thrust Selection

Motor Selection

High-Temperature Design

Reversible Fan Configuration

Noise Control

Mounting Bracket Design

Electrical Control Configuration

VFD / Soft Starter Configuration

Technical Documentation

Export Packaging

Installation Guidance

Project-Based Technical Support

Request a Quote →